
Hot Spring Watkins Replacement Water Check Valve for s Spa, 3/4 - 35233
Options
1 availableAbout this item
- Item 35233
- This 3/4" water check valve is installed in the inlet side of the circulation pumps plumbing to prevent the back flow of water through the circulation pump once the jet pump is activated
- Works on Tiger River Spas, Hot Spring Spas, and Limelight Spas.
- All water check valves have arrows stamped on the outside to indicate the direction of flow which should be pointer towards the circulation pump.
- Troubling Shooting: The symptoms of a non-operative check valve are; * Water Leak - If water is leaking from around the check valve, it should be replaced. * Rattling - A rattling check valve indicates that water is not being allowed to flow properly past/ through the check valve. * Verify the check valve is installed with the flow in the correct direction. * Heater High-Limit Tripping - Poor water flow through the check valve could lead to heater high-limit tripping. Ensure the check valve is n
Product description
Product description This 3/4" water check valve is installed in the inlet side of the circulation pumps plumbing to prevent the back flow of water through the circulation pump once the jet pump is activated. All water check valves have arrows stamped on the outside to indicate the direction of flow which should be pointer towards the circulation pump. These low flow water check valves come in two sizes (1/2" #HTCP70173 & this 3/4"). This is for a Single Watkins Water Check Valve, 3/4" OEM Replacement High Grade Quality that's made to last!! Troubling Shooting: The symptoms of a non-operative check valve are; * Water Leak - If water is leaking from around the check valve, it should be replaced. * Rattling - A rattling check valve indicates that water is not being allowed to flow properly past/ through the check valve. * Verify the check valve is installed with the flow in the correct direction. * Heater High-Limit Tripping - Poor water flow through the check valve could lead to heater high-limit tripping. Ensure the check valve is not block by debris and operating properly. * Surging jet pump (on spas equipped with a flow switch). Directions Install the water check valve in the inlet side of the circulation pumps plumbing with the arrow pointing towards the circulation pump.
Product details
Customer reviews
What customers say about Bigamart
10 Trustpilot reviews total, with 2 shown at a time.
I wrote to Bigamart's customer support and they accompanied the process of reshipping the item until it finally arrived. I felt a genuine effort to solve the problem till it was finally solved.
The package was here in Australia from England in a few days โ so quick! Something was missing and they refunded it straight away. Pretty happy with these guys.
You might also like
Similar items




